Define
If you have an unknown barcode or are creating a custom barcode, the Define screen opens.
When you create a custom barcode or scan a barcode that is not known by the cloud server, you
need to define the media attributes manually.
Note:
The stock only needs to be defined once. After you set up the stock for the first time,
the data is stored in the PredictPrint Cloud Server. You can scan the associated barcode to
obtain the stock information automatically.
Load
On the Load screen, you can specify the trays where you have loaded the stock. The paper tray
options are Trays 1–3, 6–9, Tray 5 (Bypass), or Inserter Tray T1. You can load the media before or
after you scan a barcode or define the stock properties. For multiple tray loading, you can load all
trays or scan the barcodes in any order. You can load all trays or scan the barcodes in any order, as
follows:
• If you scan the barcodes first: Scan all barcodes. To load the media in the correct trays, follow
the Stock Wizard.
• If you load the trays first: Load all stocks in the appropriate trays. To verify the barcodes for the
loaded stocks, follow the Stock Wizard screens.
Setup
On the Setup screen, you can verify that the stock properties are correct. You can select the
orientation of the paper that feeds into the press:
Long Edge Feed
or
Short Edge Feed
. On the
Setup screen, the Stock Wizard performs automatic setup routines that are recommended for the
stock. The automatic setup routines include:
• Tray Programming
• Alignment Setup
• Secondary Transfer Voltage Adjustment
• Calibration and Profiling
Advanced
On the Advanced screen, the Stock Wizard performs semi-automatic setup routines that are
recommended for the stock. The advanced setup routines include:
• Advanced Alignment for Multiple Profiles
• Trail Edge Transfer Output Adjustment
• Aligner Roll Pressure Adjustment
• Paper Speed Transfer Adjustment
• Fuser Temperature Adjustment
• Regi-Loop Adjustment
• Pre Gate Roll Control
• Tray Air Assist Adjustment
• Tray Heater Adjustment
Note:
If there are no semi-automatic setup routines to perform, the Calibration and
Profiling process is done on the Setup screen.
78