Auto
Select this to detect the Ethernet transmission rate automatically.
100 Mbps Full-Duplex
Select this to set 100BASE-TX (Full Duplex) as the default value.
100 Mbps Half-Duplex
Select this to set 100BASE-TX (Half Duplex) as the default value.
10 Mbps Full-Duplex
Select this to set 10BASE-T (Full Duplex) as the default value.
10 Mbps Half-Duplex
Select this to set 10BASE-T (Half Duplex) as the default value.
TCP/IP - IP Mode
Allows you to select an IP operation mode. Selecting [Dual Stack] enables both IPv4 and
IPv6 communications.
IPv4 Mode
Select this option for IPv4 environment.
IPv6 Mode
Select this option for IPv6 environment.
Dual Stack
Select this option for IPv4, IPv6, or mixed IPv4/IPv6 environment.
IPv4 - IP Address Resolution
Allows you to set the method for obtaining the IP address, subnet mask, and gateway
address.
DHCP
The address, subnet mask, and gateway address will automatically be set via DHCP.
BOOTP
The address, subnet mask, and gateway address will automatically be set via BOOTP.
RARP
The address, subnet mask, and gateway address will automatically be set via RARP.
DHCP/Autonet
The address, subnet mask, and gateway address will automatically be set via DHCP/Autonet.
If the machine fails to communicate with the DHCP server, the Auto IP function is
automatically enabled and the machine is assigned an IP address (169.254.xxx.xxx). When
communication between the machine and the DHCP server is recovered, the machine is re-
assigned an IP address, a subnet mask, and a gateway address by the DHCP server.
STATIC
Allows you to manually specify an IP address, a subnet mask, and a gateway address.
Note
•
[IPv4 - Subnet Mask] and [IPv4 - Gateway Address] are configurable when [IPv4 - IP
Address] is set.
IPv4 - IP Address
Enter the IP address using the numeric keypad when selecting [STATIC] at [IPv4 - IP
Address Resolution].
Note
•
Enter the address in the format "xxx.xxx.xxx.xxx", where "xxx" is a numeric value in the
range of 0 to 255.
•
Specify an IP address using numbers (0 to 9) and periods (.). If you mistyped a character on
the screen, select [Backspace] to delete the character.
Содержание DocuCentre-III C4100
Страница 1: ...DocuCentre III C4100 C3100 Administrator Guide...
Страница 12: ......
Страница 40: ...2 Paper and Other Media 38 Paper and Other Media 2 14 Select Close to return to the All Services screen...
Страница 72: ......
Страница 216: ......
Страница 224: ......
Страница 250: ......
Страница 262: ......
Страница 276: ......
Страница 292: ......
Страница 320: ......
Страница 444: ......