Error Code
399
P
rob
le
m Solving
14
027-513
O
[Cause] The machine failed to transfer data using [SMB] of the
[Scan to PC] feature because access to the SMB server
was not permitted.
When the server is Macintosh, a folder with the same
name as the specified file name may exist on the server.
[Remedy] Change the settings so that a file or a folder can be read
and written at the save location.
When the server is Macintosh, change the folder name on
the server, or the file name to be transferred.
027-514
O
[Cause] The machine failed to transfer data using [SMB] of the
[Scan to PC] feature because the machine could not
resolve the host name or the server name of the SMB
server when accessing the DNS.
[Remedy] Check the connection to the DNS. Check if the forwarding
destination SMB server name has been registered on the
DNS.
027-515
O
[Cause] During the transfer using [SMB] of the [Scan to PC]
feature, accessing the DNS failed because the DNS server
was not set correctly.
[Remedy] Set the DNS server address. Or, specify the destination
SMB server address using its IP address.
Error Code
Category
Cause and Remedy
C P F S M O
* If the error persists after following the listed solution, contact our Customer Support Center. The contact number is
printed on the label or card attached on the machine.
Содержание DocuCentre-III C4100
Страница 1: ...DocuCentre III C4100 C3100 Administrator Guide...
Страница 12: ......
Страница 40: ...2 Paper and Other Media 38 Paper and Other Media 2 14 Select Close to return to the All Services screen...
Страница 72: ......
Страница 216: ......
Страница 224: ......
Страница 250: ......
Страница 262: ......
Страница 276: ......
Страница 292: ......
Страница 320: ......
Страница 444: ......