INSTALLATION
1-4
Activating the Display
Your instrument is shipped with the battery installed. The instrument should remain in “Sleep
Mode” throughout the shipment. After the contents of the carrying case are unpacked, you
should “Wake Up” the instrument. Simply press the Enter key and the Start Up Display should
appear after a few seconds. In the event the instrument was in “Active Mode” throughout the
shipment, the battery may be depleted. In this case, you need to charge the battery
immediately before beginning normal operation. Follow the instructions listed in “Charging
the Battery” on page 1-5.
Optimizing Battery Performance
The advanced power management of the ColorEye XTH operates differently from
conventional systems. NiMH batteries tend to discharge more rapidly from the initial fully
charged condition. The discharge rate then slows dramatically, providing more
measurements from 60% capacity down to zero capacity. The net effect is more overall
measurements and extended battery life than conventional batteries. This power
management system is designed to optimize battery life. In fact, even when the battery
gauge displays less than 10% capacity, there is ample power for more than 100
measurements. To help prolong battery life and reduce memory effects we suggest
periodically running the batteries to full discharge -- the point at which the "Low Battery
Alarm" condition is reached.
Although you may have fully discharged the batteries, you can continue to use the ColorEye
XTH without having to remove the batteries. Simply insert the power supply/charger cable
into the ColorEye XTH power connector and charging begins. You can continue to use the
ColorEye XTH while the batteries are charging. For more information, refer to “Charging a
Battery Installed In the Instrument” on page 1-5.
You should always charge the battery while
it is installed in the instrument. If you remove the battery, any stored measurement data in the
instrument will be lost.
Battery Safeguards and Recommendations
This section lists the most important cautions and notes that will help you protect your battery
and yourself during instrument operation, battery replacement and battery charging. Please
read it carefully.
a. Do not charge the battery packs with a battery charger not specified or
approved by
X-Rite
.
b. You should always charge the battery while it is still installed in the
instrument. If you remove the battery, any stored measurement data on the
instrument will be lost.
c. Do not burn the battery pack.
d. Do not short circuit the terminals.
e. Do not damage or drop the instrument or subject it to mechanical vibration.
f.
Charging temperature range is 50
°
to 95
°
F (10
°
to 35
°
C). The lower the
temperature, the longer the recharging time.
g. The battery pack is normally warm after charging or use.
h. Store battery packs in a cool dry place. Long exposure to high
temperatures increases battery discharge and reduces battery life.
i.
Total battery discharge may naturally occur during long storage. Discharge
batteries before storing them to extend battery life.
Содержание COLOREYE XTH
Страница 1: ...COLOREYE XTH Spectrophotometer OPERATION MANUAL ...
Страница 20: ...INSTALLATION 1 16 ...
Страница 46: ...OPERATION 3 6 ...
Страница 54: ...MAINTENANCE 4 8 ...
Страница 57: ...A 3 APPENDIX Color Check Record Temperature Aperture Size Serial Number of Instrument Date L a b ...
Страница 58: ...APPENDIX A 4 ...
Страница 62: ......
Страница 63: ......