8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 93
Section 8.5
: Level “Extended cleaning parameters 1” (r parameters)
Drain valve settings
Def.
r23 Behavior in pre-rinse 2 when fetching water via the reservoir
0: Drain valve is closed
1: Drain valve is open
1
r24 Switching mode drain valve 1
0: normally closed
1: currentless open
0
r25 Switching mode drain valve 2
0: normally closed
1: currentless open
0
r26 Switch-on delay drain valve
(rinsing cycle 0 and 9)
Time delay with which the drain valve opens after the agitator and
flushing pump have started.
0: deactivated
1..60 sec.: Delay time of the activation of the drain valve
0
Settings to start cleaning
Def.
r27
Cleaning enable via digital input
(see section 9.15.1)
0: deactivated
1: activated
0
r28
Activation quick cleaning programme via button
0: deactivated
1: 1x pre-rinse 1
(cleaning stage 1)
2: 1x pre-rinse 2
(cleaning stage 2)
3: 1x after-rinse
(cleaning stage 8)
4: 1x rinse-out
(cleaning stage 9)
5: 2x pre-rinse 1
(cleaning stage 1)
6: 2x pre-rinse 2
(cleaning stage 2)
7: 2x after-rinse
(cleaning stage 8)
8: 2x rinse-out
(cleaning stage 9)
0
If a quick cleaning pro-
gramme (1..8) is parame-
terized here, it can be
started as follows:
Hold down SET-button,
right after that press
button CLEANING