8. Setting of parameters
Page 102
105204
– WTS-300-E - V4.1 - 20.01.2022
8.8
Level “General tank monitor parameters” (h parameters)
Fault messages tank monitor during cooling mode
Fault
Range
Def.
h20 Target temperature 1st milking *
(Starting from this point the monitoring of the over / under temper-
ature begins [h25] + [h29])
F20
0 .. 30,0 °C
5,0
h21 Max. time to reach target temperature [h20] *
0..999 min.
120
h23 Max. overtemperature for a time
(from cooling start) *
Start of monitoring from the start of cooling
F23
0 .. 30,0 °C
10,0
h24 Max. time of overtemperature
(from cooling start)
*
0..999 min.
180
h25 Max. overtemperature with direct alarm triggering *
Start of the counter from the 1st milking
F25
0..99,9 °C
25,0
h26 Max. running time compressor cycle *
Max. total running time of all compressors from the start of cool-
ing to the collection of the milk. If the time entered is exceeded,
the alarm is triggered. Serves the service technician to determine
problems with the cooling cycles.
F26
0..99,9 h
0,0
h27 Min. undertemperature for a time *
Start of monitoring from cooling start. An alarm is triggered if the
temperature falls below the value set for longer than the time set
[h28].
F27
0..30,0 °C
2,0
h28 Max. time of undertemperature
(from cooling start) *
0..999 min
120
h29 Min. undertemperature with direct alarm triggering *
(from 1st milking) Start the counter from cooling start
F29
0..30,0 °C
0,5
h31 Max. cooling interruption *
F31
0..999 min.
60
h32 Max. time in off mode after cleaning
*
F32
0..5000 min
600
h33 Min. cleaning cycle *
F33
0 .. 250 h
78
h35
h36
Detergent monitoring alkaline by float switch
Detergent monitoring acid by float switch
0: deactivated
1: high-active
only in cleaning
2: low-active
only in cleaning
3: high-active,
permanently
4: low-active,
permanently
5: Flow switch. Feedback via the flow switch is expected
when the respective pump is activated.
F35
F36
0 .. 5
0 .. 5
0
0
h38 Max. temperature difference monitoring sensor during
cooling mode
F38
1,0 .. 5,0
2,0
Switch to level
“General tank monitor pa-
rameters”
See section 8.1
H parameters
Code: 4711
Working level
for normal daily operation
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters 1
code: C567
Extended cleaning parameters 2
code: D432
Service parameters
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5
* 0: deactivated