8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 117
Section 8.12
: Level “I / O test parameters” (o. parameters)
Test digital inputs
All inputs [o.21 to o.33] can be selected via the arrow keys and
tested as follows::
Select the desired parameters with the arrow keys.
Press the SET key briefly: '0' or '1' appears in the display (depend-
ing on the current switching state of the respective component).
Change switch state (e.g. safety switch).
The display toggles between '0' and '1'.
Press the SET key again: The display shows the current parame-
ter name again.
0: switched
1: unswitched
Range
Def.
o.21
o.22
o.23
o.24
o.25
o.26
o.27
o.28
o.29*
o.30*
o.31*
o.32*
o.33*
Test digital input 1
Test digital input 2
Test digital input 3
Test digital input 4
Test digital input 5
Test digital input 6
Test digital input 7
Test digital input 8
Test digital input 1 external I/O module
(optionally)
Test digital input 2 external I/O module
(optionally)
Test digital input 3 external I/O module
(optionally)
Test digital input 4 external I/O module
(optionally)
Test digital input 5 external I/O module
(optionally)
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
0 .. 1
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
* is only displayed if ext. I / O extension module is activated and parameterized
Set and test level inputs
Range
Def.
o.41 Level 1
-10 .. 10
0
o.42 Level 2
-10 .. 10
0
-10: less sensitive
0: normal
+10: more sensitive
Adjust sensitivity:
green LED "OK" lights up if o.41 / o.42 detects level
Test ESVAW (agitator monitoring module)
o.70* test of relay on optional ESVAW 002 or 003
o.71* Agitator 1
in watt
o.72* Agitator 2
in watt
o.73* Agitator 3
in watt
o.74* Agitator 4
in watt
* is only displayed if the agitator monitoring module is activated
and parameterized