8. Setting of parameters
Page 94
105204
– WTS-300-E - V4.1 - 20.01.2022
Section 8.5
: Level “Extended cleaning parameters 1” (r parameters)
Settings for level detection (see also section 11.6)
Def.
r29
Inertia level input
1: fast
2: medium
3: sluggish
3
r30
Sensitivity level input 1
-10: less sensitive | +10: more sensitive
0
r31
Sensitivity level input 2
-10: less sensitive | +10: more sensitive
0
r32
Timeout water intake by level
(Fault F44)
Maximum time to cleaning abort: 1 .. 60 min.
5
r33
Level monitoring at the end of the rinsing cycle
(Fault F45)
0
0: deactivated
Termination of cleaning in the event of a fault
1: Monitoring of level 1 after last rinsing stage only
2: Monitoring of level 1 after each rinsing stage
3: Monitoring of level 2 after last rinsing stage only
4: Monitoring of level 2 after each rinsing stage
No termination of cleaning in the event of a fault (only fault message)
1: Monitoring of level 1 after last rinsing stage only
2: Monitoring of level 1 after each rinsing stage
3: Monitoring of level 2 after last rinsing stage only
4: Monitoring of level 2 after each rinsing stage
r34
Monitoring of water intake time during intake
(Fault F46)
above level (not in case of “water intake via pre-hopper”)
0: deactivated
1..300: A minimum-water intake time (in seconds) is set.
If water is detected at the level electrode before this
time has elapsed, the water still continues to run
until the time has elapsed - fault F46 is reported.
0
Setting of heater
Def.
r35
Heater activation
0: no heater
1: only in main cleaning stage 1
2: in both main cleaning stages 1+2
3: in both main cleaning stages 1+2 and disinfection
1
r36
Start delay heater
Range: 0 .. 120 sec.
10
r37
Max. running time heater
(Timeout programme step “H”)
Range: 10 .. 999 min. (Fault F48)
60
r38
Heater protection via pressure switch
0: deactivated
1.. 8 sec.: Switch off the heater after x seconds without pressure
0
r39
Over temperature protection heater
(Fault F49)
To protect the heater (open in the event of a fault)
0: No protective contact
1: Protective contact active
0