6. Cleaning
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 59
n
0
1
n
0
2
n
0
3
n
1
0
n
1
1
n
1
2
n
1
3
6.6.2 Dosing of the quantity-controlled detergent and disinfectant
Settings for rinsing cycles (3 + 5 + 7)
Activate the function
"Volume-controlled detergent and disinfectant dosing"
in pa-
rameter [L110] for both main rinses and disinfection.
Select the desired detergent and disinfectant dosing quantities in parameters
[L101 to L103].
If the value '0' is entered in a parameter [L101 to L103], the corresponding deter-
gent or disinfectant is dosed via time [n101 to n103].
Set a timeout-time for dosing in parameter [L112].
If the desired detergent quantity is not achieved within the time [L112]:
- the dosing is stopped,
- the cleaning is carried out to the end,
- the fault message (F35, F36 or F37) is given.
Select 'Programme step' D1 or D2 in parameter [r20] for the dosing of the cleaning
agent.
- Programme step D1 => Add detergent AND water at the same time
- Programme step D2 => Add detergent ONLY
Detergent and disinfectant are now added in each rinse cycle according to the num-
ber of litres entered. The other programme steps remain unchanged.
6.6.3 Quantity-controlled water intake
Settings separately for each rinse cycle (0 - 9)
Activate the function
"quantity-controlled water intake"
in parameter [L105] for all
rinse cycles.
In the corresponding L-parameters [L1, L2, L12, L13... etc.], determine the desired
amount of water for the associated 'programme steps' n01, n02, n12, n13... etc.
Water is then added in each rinse cycle according to the number of litres entered.
The other programme steps remain unchanged.
NOTICE: If no water quantity is entered in one of the L-parameters, the programme
step is skipped
.
if program step D1 is selected in parameter [r20]:
Define in parameter [L104] the amount of water entering at the same time as the
detergent or disinfectant.
Set a timeout-time for water intake in parameter [L107].
If the desired litre-indication is not achieved within the time [L107], parameter
[L106] is performed as set:
0: Same timeout [L107] for all programme steps
after timeout abort of cleaning*.
F46
1: Same timeout [L107] for all programme steps
after timeout the cleaning is continued
F46
2: Individual timeout for each programme steps (adds up from the
corresponding n- parameter [n01, n02, n12, n13...] + [L107])
after timeout the cleaning is continued
F46
* Control stops at the end of cleaning. Robot remains stopped
Programme step
NOTICE