8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 95
Section 8.5
: Level “Extended cleaning parameters 1” (r parameters)
Number of passes of seperate cleaning stages
See also section 6.3
Range.
Def.
r40 Number of passes clean. stage 0: Rinse out
0 .. 5
0
r41 Number of passes clean. stage 1: Pre-rinse 1
0 .. 5
1
r42 Number of passes clean. stage 2: Pre-rinse 2
0 .. 5
0
r43 Number of passes clean. stage 3: Main rinse 1
(not changeable)
1
1
r44 Number of passes clean. stage 4: Intermed. rinse 1
0 .. 5
0
r45 Number of passes clean. stage 5: Main rinse 2
0 .. 1
0
r46 Number of passes clean. stage 6: Intermed. rinse 2
0 .. 5
0
r47 Number of passes clean. stage 7: Disinfection
0 .. 1
0
r48 Number of passes clean. stage 8: After-rinse
0 .. 5
1
r49 Number of passes clean. stage 9: Rinse out
0 .. 5
0
Selection of water valve (cold / hot water)
Range.
Def.
r50 Valve selection clean. stage 0: Rinse out
1 .. 7
1
r51 Valve selection clean. stage 1: Pre-rinse 1
1 .. 7
1
r52 Valve selection clean. stage 2: Pre-rinse 2
1 .. 7
2
r53 Valve selection clean. stage 3: Main rinse 1
1 .. 7
2
r54 Valve selection clean. stage 4: Intermed. rinse 1
1 .. 7
1
r55 Valve selection clean. stage 5: Main rinse 2
1 .. 7
1
r56 Valve selection clean. stage 6: Intermed. rinse 2
1 .. 7
1
r57 Valve selection clean. stage 7: Disinfection
1 .. 7
1
r58 Valve selection clean. stage 8: After-rinse
1 .. 7
1
r59 Valve selection clean. stage 9: Rinse out
1: Cold water
2: Warm water
3: Cold and warm water (mixed)
4: Hot water / Beaker dosing
5: Hot water and cold water
6: Hot water and warm water
7: Hot water and warm water and cold water
1 .. 7
1
Selection of drain valve
Range.
Def.
r60 Drain valve select. clean. stage 0: Rinse out
1 .. 2
1
r61 Drain valve select. clean. stage 1: Pre-rinse 1
1 .. 2
1
r62 Drain valve select. clean. stage 2: Pre-rinse 2
1 .. 2
1
r63 Drain valve select. clean. stage 3: Main rinse 1
1 .. 2
1
r64 Drain valve select. clean. stage 4: Intermed. rinse 1
1 .. 2
1
r65 Drain valve select. clean. stage 5: Main rinse 2
1 .. 2
1
r66 Drain valve select. clean. stage 6: Intermed. rinse 2
1 .. 2
1
r67 Drain valve select. clean. stage 7: Disinfection
1 .. 2
1
r68 Drain valve select. clean. stage 8: After-rinse
1 .. 2
1
r69
Drain valve select. clean. stage 9: Rinse out
1: Drain valve 1
2: Drain valve 2
1 .. 2
1
From option 4 onwards,
the function A 16 (hot
water valve) must addi-
tionally be assigned to
one of the relays in the A
parameters.
In case of selection 2,
the function A 15 (drain
valve) must additionally
be assigned to one of the
relays in the A parame-
ters.