7. Tank monitor and general fault handling
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 65
Section 7.2: Tank monitor: Milk removal YES or NO
Cr informative alarm -
Milk must not be taken out.
The driver goes to the WTS-300 and checks the tank monitor.
Green and red LEDs are flashing, an error code blinks in the display and, de-
pending on the circumstances, a horn may sound
The driver informs the farmer -> Farmer and driver investigate the cause of the
critical and informative alarms. (The critical alarm codes are taken from the dis-
play and identified using the fault table. See section 8.10)
The farmer and driver then decide together whether the milk can be transferred
to the tanker, despite the alarm.
The farmer first presses the RESET button to cancel the critical alarm -> the
horn switches of.
The farmer presses the RESET button again -> the red LED is lit continuously.
The farmer then cancels the informative alarm -> the green LED turns off.
Once the tank is emptied the washing process must be started.
It is only when the cleaning cycle is active for at least 10 minutes that the tank
monitor resets all critical alarms.
Green = flashing
Red = flashing
cr informative alarm
(press RESET button)
after RESET
Green = flashing
Red = on
cr informative alarm
(press RESET button)
after second RESET
Green = off
Red = on
cr informative alarm