8. Setting of parameters
Page 74
105204
– WTS-300-E - V4.1 - 20.01.2022
8.
Setting of parameters
8.1 Change and save parameter values
The WTS-300 is configured in 11 different parameter levels.
To change parameters in one of the lower levels, enter the corresponding 'level code'
Enter the level code
Proceed as follows (control must be in OFF mode):
Press the "OFF" button for 5 seconds:
The display shows '0000' - the first '0' flashes.
Use the arrow keys to set the first digit or letter of the desired code
Confirm the correct digit with "SET".
The set digit has been accepted - the second '0' flashes.
Use arrow keys to set the second digit.
Set third and fourth digits as well:
The first parameter of the selected level now appears.
If an incorrect code is entered, the control switches back to the OFF mode.
Working level
for normal daily operation
CODE
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters 1
code: C567
Extended cleaning parameters 2
code: D432
Service parameters
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5