Specialized Concentrated Focused
「
42
」
Operation
3) Repeat the above operation to each tool.
Related parameter
Parameter
Definition
Setting Range
Cali Block Thickness
It specifies the height between tool sensor and work
table.
0~100 mm
When there is no tool sensor, please move the tool manually to the workpiece surface and press F4
under [Tool Cali] interface, the current Z-axis machine coordinate recorded in tool offset directly. After
that, users can check the set tool offset in [Tool View Table] under [Parameter] function section, shown
as below:
Fig. 3-26 Tool View Table
3.7.4 First Presetting/ Second Presetting
The operation steps are as below:
Firstly, manually move Z axis to workpiece surface, and then confirm the workpiece origin by floating
presetting or manual clear (the method for manual clear: press F1 [Clear], and then press F3 [Z
Clear] in the new pop-up manipulation button bar).
Secondly, press F6 [Tool Cali], and then press F1 [First Calli] to execute the first calibration in the
new pop-up manipulation button bar, and then the system will record the current workpiece
coordinate value of Z axis automatically, as shown in Fig. 3-27. The system ends this process
automatically.