Specialized Concentrated Focused
「
24
」
Operation
Rotary Axis
The pulse equivalent of rotary axis refers to the rotation degree of the axis clamping the workpiece
corresponding to each pulse. The difference of rotary axis movement from linear axis movement lies in
that the screw pitch of rotary axis is 360 degrees. Therefore, in calculating rotary axis pulse equivalent,
you just need to replace screw pitch with 360.
For Stepping Motor
360
Pulse Equivalent
360
Subdivision Mechanical Deceleration Ratio
Stepping Angle
For Servo Motor
B
Encoder Resolution Pulse Equivalent
Electronic Gear Ratio
Mechanical Deceleration Ratio
A
360
Related Parameters
Parameter
Definition
Setting Range
X-axis pulse equivelant
It refers to the displacement or angle generated on
the X axis per control pulse.
0.0001~999
Y-axis pulse equivelant
It refers to the displacement or angle generated on
the Y axis per control pulse.
0.0001~999
Z-axis pulse equivelant
It refers to the displacement or angle generated on
the Z axis per control pulse.
0.0001~999
CAUTION
The setting value of pulse equivalent must be matching with that of the electronic gear ratio of servo driver or that
of subdivision of stepping driver.
3.3.3 Upper & Lower Limit Setting of Workbench Range
Workbench range refers to the valid machining range of machine tool along X, Y, and Z directions, and
the system will carry out software limit in terms of this range in order to protect the machine.
Related Parameters
Parameter
Definition
Setting Range
Workbench range upper limit(X)
They set the upper limit for the working
range of each axis.
0~100000
Workbench range upper limit(Y)
Workbench range upper limit(Z)
Workbench range lower limit(X)
They set the lower limit for the working
range of each axis.
-100000~100000
Workbench range lower limit(Y)