Specialized Concentrated Focused
Parameter Overview
「
133
」
Name
Setting Range
Default
Effect Time
Reference
Max X-axis speed
6~15000 mm/min
15000
After reboot
Max Y-axis speed
6~15000 mm/min
15000
After reboot
Max Z-axis speed
Z down speed~15000 mm/min
15000
After reboot
Reference velocity
0.1667~10000 mm/min
500
After reboot
X
axis
reference
velocity in corner
0.1667~10000 mm/min
500
After reboot
Y
axis
reference
velocity in corner
0.1667~10000 mm/min
500
After reboot
Z
axis
reference
velocity in corner
0.1667~10000 mm/min
500
After reboot
Reference
circular
speed
Yes: Valid; No: Invalid
Yes
Immediately
Reference
circle
speed
-
Immediately
Limit max velocity for
small lines
Yes: Valid; No: Invalid
Yes
Immediately
Length for limit max
velocity
0.001~100000 mm
2
Immediately
Path smoothing time
0~2 sec
0
Immediately
Arc radius tolerance
0~999 mm
2
Immediately
Enable IJK increment
mode
Yes: Valid; No: Invalid
Yes
Immediately
Stop spindle while
pausing
Yes: Valid; No: Invalid
Yes
After reboot
Stop spindle while
stopping
Yes: Valid; No: Invalid
Yes
After reboot
Is open coolant while
starting
Yes: Valid; No: Invalid
No
After reboot
Is close coolant while
stopping
Yes: Valid; No: Invalid
No
After reboot
Whether
to
stop
spindle at end
Yes: Stop; No: Not stop
Yes
Immediately
Max. spindle speed
10000~999999 r/min
24000
After reboot
Spindle
start/
stop
time
0~60000 ms
5000
Immediately
Center spindle rev
0~ Max. spindle speed r/min
500
Immediately