Specialized Concentrated Focused
「
36
」
Operation
Fig. 3-20 Parameters Setting Area-G00 Speed Setting
Its concrete setting method is the same as that of feed speed, which will be omitted.
3.6.3 Parameters Specification
Except the feed rate and traverse speed, the other involved parameters can be divided into following 4
types: velocity, acceleration, reference circle & circular speed limit, interpolation algorithm.
Related Parameters (Velocity)
Parameter
Definition
Setting Range
Manual high speed
There are two modes for option under manual
mode: low speed and high speed, which can be
switched by pressing acceleration key. The system
default running speed mode is manual low speed
Manual low speed
~max. speed of axes
Manual low speed
0.001~Manual high
speed
Dry running speed
The speed of machine tool in dry running
0.001~Max. Speed of
machine tool
Machining speed
Gxx speed
0.0~Dry running speed
Startup speed
The max. achievable speed of stepping motor in
startup without acceleration
0.001~Dry running
speed
Max machining
speed
The maximum feeding speed when machining
3000~15000 mm/min
Full feedrate for
G00
When it is set as “True”, G00 override will be not
controlled by the override switch
True: Not controlled
False: Controlled
Feedrate is valid for
manual mode
Feedrate override is valid under stepping and jog
modes
True: Valid
False: Invalid
Use default speed
It specifies whether to adopt the default G00 speed
and Gxx speed, ignoring the file speed
True: Use
False: Not use
Use default spindle
speed
It specifies whether to adopt the default spindle
speed, ignoring S commands in the file
True: Use
False: Not use
Z down speed
It sets the plunge rate under G01
0~100000
Use Z down speed
Whether to use Z down speed under G01 plunge
cut
True: Use
False: Not use
Max Z-axis speed
It specifies the max. allowable speed of Z axis
0.001~100000
mm/min
Plunge speed
option
The options of Z down speed
0:not disposed;
1:direct-Z-motion only;
2:general Z-down
motion
Z deceleration
distance
It is the distance from where the machine tool
begins to decelerate to the target position during
positioning
0~999 mm