CHAPTER 3 - INSTALLATION AND CONNECTION
29
Use the minimum recommended panel dimensions and its cooling
requirements:
Table 3.3
- Panel Dimensions and Cooling Requirements
Table 3.4
- Power losses for panel fan dimensioning
NOTE!
The fans above are recommended for duties of 10 starts/hour with 3 x In
of the Soft-Starter during 30s.
Power Losses
In the
eletronics
Fan Power
Total Power losses in
the SCRs in Full
Voltage
Average power
losses-10 starts/h
3xln@30s
Total average power
losses-10 starts/h
3xIn@30s
Model
W
W
W
W
W
SSW-06.0085
33
-
0 = By-pass
76.5
109.5
SSW-06.0130
33
-
0 = By-pass
117.0
150.0
SSW-06.0170
33
-
0 = By-pass
153.0
186.0
SSW-06.0205
33
-
0 = By-pass
184.5
217.5
SSW-06.0255
33
58
528mA@110Vac
264mA@220Vac
0 = By-pass
229.5
320.5
SSW-06.0312
33
58
528mA@110Vac
264mA@220Vac
0 = By-pass
280.8
371.8
SSW-06.0365
33
58
528mA@110Vac
264mA@220Vac
0 = By-pass
328.5
419.5
SSW-06.0412
33
58
528mA@110Vac
264mA@220Vac
0 = By-pass
370.8
461.8
SSW-06.0480
33
58
528mA@110Vac
264mA@220Vac
0 = By-pass
432.0
523.0
SSW-06.0604
33
58
528mA@110Vac
264mA@220Vac
0 = By-pass
543.6
634.6
SSW-06.0670
33
87
396mA@110Vac
972mA@220Vac
0 = By-pass
603.0
723.0
SSW-06.0820
33
87
396mA@110Vac
1391mA@220Vac
0 = By-pass
738.0
858.0
SSW-06.0950
33
160
727mA@110Vac
955mA@220Vac
3420
427.5
3898.0
SSW-06.1100
33
210
955mA@220Vac
3960
495.0
4533.0
SSW-06.1400
33
210
955mA@220Vac
5040
630.0
5703.0
Cooling CFM
(m
3
/min)
-
-
-
-
-
1757.30 (49.80)
1757.30 (49.80)
2648.44 (75.00)
Model
SSW-06.0085
SSW-06.0130
SSW-06.0170
SSW-06.0205
SSW-06.0255
SSW-06.0312
SSW-06.0365
SSW-06.0412
SSW-06.0480
SSW-06.0604
SSW-06.0670
SSW-06.0820
SSW-06.0950
SSW-06.1100
SSW-06.1400
Panel Dimensions
Width
Hiegth
Depth
mm (in)
mm (in)
mm (in)
600
1200
400
(23.62)
(47.24)
(15.75)
600 (23.62)
1600 (63.00) 600 (23.62)
600
2000
600
(23.62)
(78.74)
(23.62)
600
2000
600
(23.62)
(78.74)
(23.62)
800
2000
600
(31.50)
(78.74)
(23.62)
800 (31.50)
2000 (78.74)
600 (23.62)
800
2000
600
(31.50)
(78.74)
(23.62)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]