SSW-06 - QUICK PARAMETER REFERENCE
14
Parameter
Description
Adjustable Range
Factory
Unit
User´s
Page
Setting
Setting
7=Fault
8=Fieldbus
9=Serial
Soft-Starter Data
P295
(1)(2)
SSW Rated Current
0=10A
11=312A
According to
A
103
1=16A
12=365A
Soft-Starter
2=23A
13=412A
Rated Current
3=30A
14=480A
4=45A
15=604A
5=60A
16=670A
6=85A
17=820A
7=130A
18=954A
8=170A
19=1100A
9=205A
20=1411A
10=255A
P296
(1) (2)
Rated Voltage
0=220/575V
According to
V
103
1=575/690V
Soft-Starter
Voltage
PARÂMETROS DE COMUNICAÇÃO SERIAL P300 a P399
P308
(1)(2)
Soft-Starter Address on the Serial
1 to 247
1
-
104
Communication Network
P309
(1)(2)
Fieldbus Communication
0=Inactive
0=Inactive
-
104
Board Enabling
1=Profibus-DP
(1 Inputs and 1 Outputs)
2=Profibus-DP
(4 Inputs and 4 Outputs)
3=Profibus-DP
(7 Inputs and 7 Outputs)
4=DeviceNet
(1 Inputs and 1 Outputs)
5=DeviceNet
(4 Inputs and 4 Outputs)
6=DeviceNet
(7 Inputs and 7 Outputs)
P312
(1)(2)
Protocol Type and Serial
1=Modbus-RTU
1=Modbus-RTU
104
Communication Transfer Rate
(9600bps, no parity)
(9600bps,
2=Modbus-RTU
no parity)
(9600bps, odd)
3=Modbus-RTU
(9600bps, even)
4=Modbus-RTU
(19200bps, no parity)
5=Modbus-RTU
(19200bps, odd)
6=Modbus-RTU
(19200bps, even)
7=Modbus-RTU
(38400bps, no parity)
8=Modbus-RTU
(38400bps, odd)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]