CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
118
Range
[Factory Setting]
Parameter
Unit
Description / Notes
Figure 6.28 –
Thermal Protection Classes for cold motor
Class 45
Class 40
Class 35
Class 30
Class 25
Class 20
Class 15
Class 10
Class 5
Current
x In
F.S.=1
F.S.=1,15
9x
9x
8x
8x
10x
7x
7x
6x
6x
5x
5x
4x
4x
3x
3x
2x
2x
1x
1x
1
10
100
1000
Time
t(s)
Class
3xIn
5xIn
7xIn
40
135s
48.1s
24.5s
30
101.2s
36.1s
18.3s
Table 6.37
– Thermal Protection Class Times for cold motor with S.F.=1.0
10
33.7s
12s
6.1s
20
67.5s
24s
12.2s
Table 6.38
– Thermal Protection Class Times for cold motor with S.F.=1.15.
Class
3xIn
5xIn
7xIn
40
180.2s
63.6s
32.4s
30
135.1s
47.7s
24.3s
10
45.1s
15.9s
8.1s
20
90.1s
31.8s
16.2s