Quick Reference of Parameters
0-2 | SRW 01
0
Parameter
Description
Adjustable Range
Factory
Setting
User
Setting
Proprieties Page
P061
Number of Overload Trips
0 to 65535
-
RO
P062
Number of Current Imbalance Trips 0 to 65535
-
RO
P063
Number of Earth Fault Trips
0 to 65535
-
RO
P064
Number of Phase Loss (Current)
Trips
0 to 65535
-
RO
P065
Number of Overcurrent Trips
0 to 65535
-
RO
P066
Number of Undercurrent Trips
0 to 65535
-
RO
P067
Number of Frequency Out of Range
Trips
0 to 65535
-
RO
P068
Number of PTC Trips
0 to 65535
-
RO
P069
Number of Earth Leakage Trips
0 to 65535
-
RO
P070
Number of External Fault Trips
0 to 65535
-
RO
P071
Trip Status 1 (binary)
bit0 = PTC
bit1 = Out of Frequency
bit2 = Undercurrent
bit3 = Overcurrent
-
RO
P072
Trip Status 2 (binary)
bit0 = Phase Loss (Current)
bit1 = Current Imbalance
bit2 = Earth Fault
bit3 = Overload
-
RO
P073
Trip Status 3 (binary)
bit0 = Earth Leakage
bit1 = External Fault
bit2 = Trip Test
bit3 = Phase Sequence
-
RO
P075
Alarm Status 1 (binary)
bit0 = PTC
bit1 = Out of Frequency
bit2 = Undercurrent
bit3 = Overcurrent
-
RO
P076
Alarm Status 2 (binary)
bit0 = Phase Loss (Current)
bit1 = Current Imbalance
bit2 = Earth Fault
bit3 = Overload
-
RO
P077
Alarm Status 3 (binary)
bit0 = Earth Leakage
bit1 = External Fault
bit2 = No Function
bit3 = No Function
-
RO
P078
General Trip Status 2
0 to 65535
-
RO
P079
General Alarm Status 2
0 to 65535
-
RO
P080
General Trip Status
0 to 65535
-
RO
P081
General Alarm Status
0 to 65535
-
RO
P082
Total Number of Trips
0 to 65535
-
RO
P084
Communication Protocol
0 = None
1 = Modbus-RTU
2 = DeviceNet
3 = Profibus DP
4 = Modbus-TCP
5 = Ethernet/IP
6 = ProfiNet IO
-
RO
P085
Type of Digital Inputs UC
0 = Invalid
1 = Invalid
2 = 24 Vdc
3 = 110 Vac
-
RO
P086
Digital Inputs I5 to I10 Status
(decimal)
0 to 63
-
RO
P087
Digital Outputs O5 to O8 Status
(binary)
bit0 = O5
bit1 = O6
bit2 = O7
bit3 = O8
-
RO
P100
Number of Voltage Unbalance
0 to 65535
-
RO
P101
Number of Phase Loss (Voltage)
0 to 65535
-
RO
P102
Number of Overvoltage Trips
0 to 65535
-
RO
P103
Number of Undervoltage Trips
0 to 65535
-
RO