![Visonic PowerMaster-360R Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/visonic/powermaster-360r/powermaster-360r_installers-manual_1032858079.webp)
APPENDIX G. Sabbath mode
D-307083 PowerMaster-360R Installer's Guide
79
APPENDIX G.
Sabbath mode
G1. General guidance
The Sabbath Mode allows you to use the alarm system without violating the Sabbath. The basic feature of this alarm
system is that the PIR sensors are not activated during Disarm mode.
The method of installation, as illustrated in the drawing below, is used in order to prevent transmission from the magnetic
contact device. The MC-302E device is used only as a transmitting device to report the status of the door to the control
panel. A wired magnetic contact is connected to the input of the MC-302E device and an open/close switch is connected
in parallel to the MC-302E input.
Note:
Before the Sabbath, closing the circuit neutralizes the detector’s magnet. You can use the front door without
violating the Sabbath. On the Sabbath day itself, you can open the switch to allow the door to be protected. This operation
is permitted on the Sabbath and also when the control panel is armed.
G2. Connection
1.
Enroll an MC-302E to the PowerMaster-360R control panel (see section 4.4.2).
2.
Configure the Input #1 setting option of the MC-302E to Normally Closed (refer to the MC-302E Installation
Instructions, section 2.3).
3.
Connect to the MC-302E a wired magnetic contact to be installed on the door and that is operated by opening/closing
the door (see drawing below).
4.
An open/close switch must be connected in parallel to the input of the MC-302E.
Wiring Setup
A.
MC-302E device
B.
Wired magnetic contact
C.
Fixed frame
D.
Moving part
E.
Open/close switch
E1.
Closed
E2.
Open
G3. Arming the system by sabbath clock
1.
Enroll an MC-302E to the PowerMaster-360R control panel (see section 4.4.2).
2.
Configure the Zone Type to 11.Arming Key (see section 4.4.2)
3.
Configure the Input #1 setting option of the MC-302E to Normally Open (refer to the MC-302E Installation Instructions,
section 2.3).
4.
From the 03:CONTROL PANEL menu, configure the 09:ARMING KEY setting option to arm HOME (see section
4.5.2).
Note:
When the alarm system is armed at night by a Sabbath clock, the open / close switch must be opened when the
door is closed.