4. Programming
42
D-307083 PowerMaster-360R Installer's Guide
4.6.4 Configuring event reporting to private users
The PowerMaster-360R system can be programmed to send various SMS event notifications such as alarm, arming or
trouble events, if a GSM option is installed. The system can send the messages also to 4 emails, MMS and SMS
telephone numbers via the server. These reports can be programmed either instead of or in addition to the reports
transmitted to the monitoring company. In this section you configure:
The specific events you wish the system to report.
The 1
st
, 2
nd
, 3
rd
, and 4
th
SMS numbers of the private subscribers.
Event notification messages to be sent to 1
st
, 2
nd
, 3
rd
, and 4
th
private emails and private MMS and SMS telephone
numbers via the server.
SMS Permission defines if the panel accepts SMS commands from any number or only from known numbers. For a
detailed description of this menu options, refer to the User’s Guide Chapter 6, section B. 12.To select and configure an
option follow the instructions below. Additional guidance is provided in section 4.6.1.
04:COMMUNICATION
4:PRIVATE REPORT
MENU item
The
4:PRIVATE REPORT
menus and sub-menus configuration is shown in the table in section 4.6.1. For a detailed
description of the menus options, refer to the User's Guide Chapter 4, section B.12.
4.6.5 Configuring motion cameras for visual alarm verification
The PowerMaster-360R can communicate to Monitoring Stations (equipped with Visonic PowerManage server) with
image clips captured by Motion Cameras (models Next CAM PG2, Next-K9 CAM PG2 and TOWER CAM PG2). The
Monitoring Station can use the video clips for verification of Burglary alarms detected by the Motion Cameras. The
system can be configured to capture image clips also upon occurrence of Non-Burglary alarms (i.e. Fire, Duress,
Emergency and Panic). The server can then forward the images to the management computer of the Monitoring
Station or to 4 private emails and/or 4 mobile phones by MMS images.
In addition, the Monitoring Station can log into the PowerManage server and request the system to provide image clips
On Demand and to forward them as defined in the PowerManage application. To protect customers' privacy, the
PowerMaster-360R can be customized to enable the On Demand View only during specific system modes (i.e. Disarm,
Home and Away) and also to a specific time window following an alarm event.
04:COMMUNICATION
5:MOTION CAMERAS
MENU item
Enter
5:MOTION CAMERAS
, select the menu you wish to configure (see guidance above and in section 4.6.1), then
refer to the table below which provides you with detailed configuration instructions.
Option
Configuration instructions
VIEW ON DEMAND
By enabling the On Demand View, you can determine during which arming modes (system
states) the On Demand View will be permitted. In the next option VIEW TIME WINDOW you can
determine when, during the permitted arming modes, the On Demand View
will be
enabled.
Options:
disabled
(default);
in all modes
;
in AWAY only
;
in HOME only
;
in HOME &
AWAY; DISARM & AWAY
;
DISARM & HOME
; and
in DISARM only
.
VIEW TIME WINDOW
VIEW TIME
WINDOW menu
appears only if VIEW
ON DEMAND was
enabled
If the On Demand View is enabled in the previous option, you can further determine whether
the On Demand View will be possible at any time during the selected arming modes (i.e.
Always) or restricted only to a specific limited time window that follows an alarm event.
Options:
Always
(default);
Alarm + 5 min.
;
Alarm + 15 min.
;
Alarm + 1 hour
VIEW OTHER ALARM
Define whether the system will capture and forward image clips also upon occurrence of Non-
Burglary alarms (i.e. Fire, Duress, Emergency and panic).
Options:
E
nable
(default)
; Disable.
KIDS COME HOME
Define that upon PIR-camera detection, the system will send up to 4 images to a 3rd party
server if the system is disarmed via keypad or proximity tag by latchkey users 5 to 8 and only
when the system was in Entry Delay or the Abort Time was enabled.
Options:
E
nable
;
Disable
(default).
Note:
At least one PIR camera must be defined as one of the following zone types:
Perim-Follow / Inter-Follow / Exit/Entry 1 / Exit/Entry 2.
UPLOAD FILM
Define whether to enable / disable the sending of images to the PowerManage server.
Options:
E
nable
(default)
; Disable
.