C1. Functional
Zones Number
64 wireless zones
Installer and User Codes
1 master installer (9999 by default)*
1 installer (8888 by default)*
1 master user, no. 1 (1111 by default)
Users nos. 2 – 48
Latchkey users 5 - 8
* Codes must not be identical
Note:
The PowerMaster-360R system allows you to authorize up to 48 people to arm and disarm the system by providing
each with a unique 4 digit personal security code (code 0000 is not allowed, maximum number of variations of PIN
codes for each user – 10000 for logical keys), and assigning them with different security levels and functionalities.
Control Facilities
Virtual or Touch Keypad, wireless keyfobs and keypads
Arming Modes
AWAY, HOME, AWAY-INSTANT, HOME-INSTANT, FORCED, BYPASS.
Alarm Types
Silent, personal panic/emergency, burglary, gas (CO), and fire.
External Siren (bell) Timeout
Programmable (4 min. by default)
Supervision
Programmable time frame for inactivity alert
Special Functions
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over Broadband and GPRS IP connections.
- Calling for help by using an emergency transmitter.
- Tracking inactivity of people.
Data Retrieval
Alarm memory, trouble, event log
Real Time Clock (RTC)
The control panel keeps and displays time and date
.
This feature is also used for
the log file by providing the date and time of each event
Battery Test
Once every 10 seconds
PowerG Receiver Range
160 ft. (50 m) internal, 6500 ft. (2000 m) external
Connectors
External:
DC Power Jack
RJ-45 Ethernet Connector
Micro USB Connector
Internal:
SIM Card Slot (part of GPRS Module)
Battery Backup Connector
C2. Wireless
RF Network
PowerG – 2-way synchronized Frequency Hopping (TDMA / FHSS)
Frequency bands (MHz)
433 – 434
868 - 869
912 – 919
Hopping frequencies
8
4
50
Region
Worldwide
Europe
North America and
selected countries
Encryption
AES-128
Maximum Tx Power
10 dBm @ 433 MHz, 14 dBm @ 868 MHz
GSM (MHz)
2G Band
3G Band
850, 900, 1800, 1900
850
1
, 900
2
, 1900
1
, 2100
2
Z-Wave (MHz) (optional)
868.4, 908.4, 921.4
Wi-Fi - optional
2.4 GHz.
Wi-Fi client for event reporting.
Wi-Fi Access Point for IP camera support only.
1
2