Programming
4.1 General guidance
This chapter explains the installer programming configuration options of your PowerMaster-360R system and how to
customize its operation to your particular needs and end user requirements.
Software configuration of the alarm system is performed using the Virtual or Touch Keypad, which contain the control
keys, numerical keypad and display. The panel includes an intrusion sounder with a Piezo sounder.
The control panel includes a partition feature. Partitioning allows you to have up to three independently controllable
areas with different user codes assigned to each partition. You can arm or disarm a partition regardless of the status of
the other partitions within the system.
You can use the Soak Test feature to test selected zones for a pre-defined period of time. If you activate a zone in
Soak Test mode, it does not initiate an alarm, siren or strobe. The zone activation is recorded in the event log and is
not reported to the Monitoring Station. The zone remains in Soak Test mode until the pre-defined period of time for the
Soak Test elapses without any alarm activation.
The zone then automatically removes itself from Soak Test mode and
returns to normal operating mode.
Software Upgrade allows you to upgrade the software of the control panel from the remote PowerManage server.
During a software upgrade,
UPGRADING…
appears on the PowerMaster-360R keypad.
Note:
A software upgrade is delayed if the control panel is armed to
AWAY
or if an AC failure occurs. To continue with
the upgrade either disarm the panel, restore the AC power or both.
Tech Tip
:
For your convenience, program the PowerMaster-360R on a work bench before the installation. You can obtain operating
power from the backup battery or from the AC/DC adapter.
ATTENTION! FIRST SWITCH ON THE CONTROL PANEL and then INSERT BATTERIES INTO ACCESSORIES
DEVICES.
The devices search for the control panel to which they are enrolled for a period of 24 hours only after you insert the
battery.
Note:
If you switch on the control panel a long time after inserting batteries into the accessories devices you must open
and then close the cover of the PowerMaster-360R to activate the tamper switch. Alternatively, remove and reinsert the
battery into the device.
4.1.1
PowerMaster-360R panel indicators and controls
LED indicators
No. Function
Power
(Green)
indicates that your system is connected to the power outlet.
Arming Status
(Flashing Red / Static Red)
indicates HOME / AWAY.
A
B
Display