5. Periodic test
D-307083 PowerMaster-360R Installer's Guide
61
5.
Periodic test
5.1 General guidance
This mode provides you with the means to conduct a periodic test of all system sirens, detectors, keyfobs, keypads,
repeaters and other peripheral devices, via the
PERIODIC TEST
menu, at least once a week and after an alarm event.
When you are instructed to perform a periodic test, walk throughout the site to check the detectors / sensors (except for
Temperature Sensors). When a detector/sensor is triggered into alarm, its name, number and the alarm reception level
should be indicated (for example,
Bathroom
,
Z19 strong
) and the buzzer should sound according to the alarm
reception level (1 of 3). Each device should be tested according to the device Installation Instructions.
To enter the
PERIODIC TEST
menu and to conduct a periodic test, proceed as follows:
Step 1
Step 2
READY
[1] Select the test to be performed
[2]
PERIODIC TEST
(enter installer /
master code)
SIRENS TEST
TEMP/LIGHT TEST
TEST ALL DEVICES
TEST ONE DEVICE
– Periodic Test
[1] Not including Siren and Temperature Sensors
[2] After reviewing all untested devices the control panel will read
<OK> TO END
. You can now do one of the
following: press
to abort the testing procedure; press
to continue the testing procedure; or press
to exit the testing procedure.
5.2 Conducting a periodic test
The PowerMaster-360R enables you to conduct the periodic test in five parts:
Siren Test
: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume).
Temp/Light Test:
For devices with temperature sensing, the panel displays the temperature of each zone in Celsius or
Fahrenheit. For devices that have both temperature and light sensing, the panel displays the temperature and light
intensity of each zone.
Test all devices:
All devices are tested.
Other Device Test:
Each of the other devices in the system is activated by the installer and the display indicates which
devices were not yet tested. The
it's me
indication helps to identify the untested devices if necessary. A counter also
indicates the number of devices that remain untested.
Email Test:
Generates an event to be sent to the predefined private email addresses.
READY
PERIODIC TEST
MENU item
To conduct a periodic test, make sure the system is disarmed and then enter the
PERIODIC TEST
menu using your
installer code (8888 by default) or master installer code (9999 by default). Immediately after entering the
PERIODIC TEST
menu, all the LEDs on the panel will momentarily light (LED test).
Option
Instructions
SIRENS TEST
You can test wireless sirens and strobes and sirens of smoke sensors.
To initiate the siren test, press
.
The display now reads
SIREN N
.
N
indicates the
zone location assigned to the siren that is currently being tested.
The first siren enrolled in the panel sounds for 3 seconds after which the PowerMaster-360R
system will automatically repeat the procedure for the next siren enrolled in the system until
all sirens are tested. You should listen to the sirens sounds and make sure that all sirens
sound.
Once all the sirens have been tested, the control panel will now test the sirens of smoke
sensors that are enrolled in the alarm system. The display now reads
Zxx: SMOKE SIREN
,
where
Zxx
indicates the zone number of the smoke sensor, and alternates with
<OK> TO
CONTINUE
. During this time, the siren of the tested smoke sensor will sound for up to one
minute.
Press
to test the siren of the next smoke sensor.
When the sirens test is complete, the display reads
SIREN TESTS END
. Press the