4. Programming
D-307083 PowerMaster-360R Installer's Guide
31
Option
Configuration instructions
Notes:
1. In some PowerMaster-360R variants, this menu is displayed in the Operation Mode only
(see section 4.14).
2. Since the Soak Test zone does not report an alarm event to the Monitoring Station, the
PowerMaster-360R will not send a cancel alarm message to the Monitoring Station even if
disarmed within the Cancel Alarm period.
39:ALARM RESET
Previously known as
RESET OPTION
The PowerMaster-360R provides you with the following configurable options for resetting the
alarm condition and rearming the system:
By the user as usual
- by user
(default). By the engineer (installer) by entering and exiting the
Installer Mode, by entering and exiting the Event Log using the Installer Code or by accessing
the system remotely via the PowerManage server using the Installer Code (
by engineer
). For
accessing the system via the PowerManage server, see the PowerManage User's Guide.
Note:
This feature is not applicable in the USA.
40:ABORT FIRE T.
Select the length of time allowed by the system to abort a Fire alarm. The PowerMaster-360R
is able to provide an abort interval that starts upon detection of a Fire event. During this interval,
the buzzer sounds a warning but the siren remains inactive and the alarm is not reported. If the
user disarms the system within the allowed abort interval, the alarm is aborted.
Options:
in 00
(default)/
30
/
60
/
90 seconds
4.5.5 Configuring siren functionality
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 4.5.1.
Option
Configuration instructions
43:PANEL SIREN
Determines whether the control panel’s built-in siren will sound alarms - "
ON
" (default) or
remain silent – "
OFF
".
Note:
Panel siren must be enabled unless an external sounder is connected to the product.
44:SIREN TIME
Previously known as
BELL TIME
Define the period of time the sirens sounds when an alarm occurs.
Options:
1
/
3
/
4
(default)/
8
/
10
/
15
/
20 minute(s)
.
Notes:
1. To comply with
EN
requirements, the Siren Time must not exceed 15 minutes.
2. For Canada, the Siren Time must be set to 8 minutes.
45:STROBE TIME
Define the length of time the strobe light flashes when an alarm occurs.
Options:
5
/
10
/
20
(default)/
40
/
60 minutes
.
46:SIREN ON LINE
Determine if the siren is activated when the phone line fails and the system is armed.
Options:
d
isable on fail
(default)
or enable on fail.
4.5.6 Configuring audible and visual user interface
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 4.5.1.
Option
Configuration instructions
51:PIEZO BEEPS
with partition disabled
Define whether or not the panel exit or entry warning beeps sound during exit and entry delays.
An additional option is to mute the warning beeps only when the system is armed “HOME”.
Options:
ON
(default),
OFF when home
(default in USA) and
OFF
,
and
OFF exit home
.
Note:
When exit beeps are OFF, the happy (success) melody still sounds toward the end of
an exit delay.
The volume level of the exit or entry beeps can be modified by pressing the
button
on the keypad to increase the volume, or by pressing the
button to decrease the
volume.