6. Maintenance
D-307083 PowerMaster-360R Installer's Guide
65
Fault
What it means
Possible Solution
Replace SIM card
Replace the GSM unit
JAMMING
A radio-frequency signal which is blocking
communication channel of sensors and
control panel is detected.
Locate the source of interference by
switching off any wireless devices (cordless
telephones, wireless ear plugs, etc.) in the
house for 2 minutes then check if trouble
continues.
Use also RF diagnostics to check signal
strength.
LOW BATTERY
The battery in a sensor, keyfob or wireless
commander is near the end of its useful life.
For AC powered devices, check that AC
power is available and connected to the
device.
Replace the device battery.
MISSING
A device or detector has not reported for
some time to the control panel.
Make sure the device is physically
present.
Check the display for device faults, for
example, low battery.
Use RF diagnostics to check the current
signal strength and during the last 24
hours.
Replace the battery.
Replace the device.
NOT NETWORKED A device was not installed or not installed
correctly, or, cannot establish
communication with the control panel after
installation.
Make sure the device is physically
present.
Use RF diagnostics to check the current
signal strength and during the last 24
hours.
Open the device cover and replace the
battery or press the tamper switch.
Enroll the device again.
RSSI LOW
The GSM communicator has detected that
GSM network signal is weak
Move the Panel and GSM unit to another
location.
SIREN AC
FAILURE
There is no power to the siren
Make sure that the AC/DC adapter is
connected properly
TAMPER OPEN
The sensor has an open tamper
Close sensor tamper
TROUBLE
The sensor reports trouble
Replace the sensor
SOAK TEST FAIL
Detector alarms when in Soak Test mode
If you wish to continue the Soak Test, no
further action should be taken.
If you wish to abort the Soak Test, disable
the Soak Test, see section 4.4.6 for details.
6.2 Replacing the backup battery
Replacement and first-time insertion of battery pack is similar, see Figure 3.1b.
Separate the panel from the base, see section 3.2 Installing the PowerMaster-360R battery and cables for details. After
inserting the new battery pack correctly, return the panel to the base and place the screw in the locked position. The
TROUBLE indicator is extinguished. However, the MEMORY message will now blink in the Virtual or Touch Keypad
display. This message is caused by the tamper alarm that is triggered when you remove the panel from the base. Clear
the message by arming the system and immediately disarming the system.
6.3 Replacing and relocating detectors
Whenever maintenance work involves replacement or re-location of detectors, always perform
a full diagnostic test
according to section
4.8
.
Remember!
A poor signal is not acceptable.