G4 Multi Channel Weighing Instrument
3-41
Range/Alternatives
Explanation and
<default value>
result of alternatives.
Menu ‘Setpoints’
NOTE: There are 16 setpoints each with the following two parameters described below.
Setp. 1 Source ( - Setp. 16 Source)
Not in use
Net Weight
Gross Weight
Display Weight
Flow Rate
Abs.Net Weight
Abs.Gross Weight
Abs.Disp.Weight
Abs.Flow Rate
< Not in use >
Defines the signal to be supervised by the setpoint.
Not in use: The setpoint is not used, any outputs set to work
with this setpoint will be off.
Net Weight: The Setpoint operates on the net weight.
Gross Weight: The Setpoint operates on the gross weight
Display Weight: The Setpoint operates on gross weight or net
weight, even if the flow rate is displayed.
Flow Rate: The Setpoint operates on the flow rate.
Abs.: Stands for Absolute, the Setpoint operates on
the absolute value of net weight, gross weight, displayed weight,
or flow rate.
Setp. 1 Scale ( - Setp. 16 Scale)
1
2
3
4
5
6
7
8
<1>
1: The setpoint is supervising scale number 1.
2: The setpoint is supervising scale number 2.
….
8: The setpoint is supervising scale number 8.
Note: This parameter is only shown if ‘Setpoint 1 Source’ is not
set to ‘Not in use’.
Содержание G4
Страница 2: ......
Страница 18: ...Technical Manual 1 14 ...
Страница 39: ...G4 Multi Channel Weighing Instrument 3 7 ...
Страница 104: ...Technical Manual 5 18 ...
Страница 158: ...Technical Manual 6 54 ...
Страница 178: ...Technical Manual 7 20 ...
Страница 186: ...Technical Manual 8 8 ...
Страница 196: ......
Страница 197: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Страница 198: ...Technical Manual ...
Страница 199: ......