G4 Multi Channel Weighing Instrument
6-13
Data type:
Integer
Data type: float
(2 reg./value)
Explanation
R/W
40132 (1 reg)
44122
Scale 8: Error code
R
40133 (1 reg)
44124
Scale 8: Status
R
40134 (3 reg)
44126
Scale 8: Gross weight
R
40137 (3 reg)
44128
Scale 8: Net weight
R
40140 (3 reg)
44130
Scale 8: Flow rate
R
40143 (3 reg)
44132
Scale 8: Input signal (mV/V)
R
40170 (3 reg)
44150
Analog output value 1
R
40173 (3 reg)
44152
Analog output value 2
R
40176 (3 reg)
44154
Analog output value 3
R
40179 (3 reg)
44156
Analog output value 4
R
40182 (1 reg)
44158
Status of inputs 11 - 18, 21 - 28
R
40183 (1 reg)
44160
Status of inputs 31 - 38, 41 - 48
R
40184 (1 reg)
44162
Status of inputs 51 - 58, 61 - 68
R
40185 (1 reg)
44164
Status of outputs 11 - 18, 21 - 28
R
40186 (1 reg)
44166
Status of outputs 31 - 38, 41 - 48
R
40187 (1 reg)
44168
Status of outputs 51 - 58, 61 - 68
R
40188 (1 reg)
44170
Level status 1 – 16
R
40189 (1 reg)
44172
Level status 17 – 32
R
40190 (1 reg)
44174
Setpoint status 1 – 8
R
40191 (1 reg)
44176
Setpoint status 9 – 16
R
40230 (1 reg)
44200
Clock: Year
R
40231 (1 reg)
44202
Clock: Month
R
40232 (1 reg)
44204
Clock: Day
R
40233 (1 reg)
44206
Clock: Hour
R
40234 (1 reg)
44208
Clock: Minute
R
42000 (1 reg)
46000
Command register
R/W *
Содержание G4
Страница 2: ......
Страница 18: ...Technical Manual 1 14 ...
Страница 39: ...G4 Multi Channel Weighing Instrument 3 7 ...
Страница 104: ...Technical Manual 5 18 ...
Страница 158: ...Technical Manual 6 54 ...
Страница 178: ...Technical Manual 7 20 ...
Страница 186: ...Technical Manual 8 8 ...
Страница 196: ......
Страница 197: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Страница 198: ...Technical Manual ...
Страница 199: ......