Weight data block (Integer format)
Byte
Content
0
Scale x: Error code
MSB
1
Scale x: Error code
2
Scale x: Status
MSB
3
Scale x: Status
4
Scale x: Data, int
MSB
5
Scale x: Data, int
6
Scale x: Data, int
7
Scale x: Data, int
8
Scale x: Data, dec
MSB
9
Scale x: Data, dec
10
Not used
11
Not used
12
Not used
13
Not used
14
Not used
15
Not used
Note: Scale Data can be (selected by parameter) Gross Weight, Net Weight,
Displayed Weight, Flow Rate Value or Input Signal.
X is the selected (by parameter) scale number for the data block.
The table above describes the data block format if the parameter ‘Data Block N Format’
is set to ‘Integer’ where ‘N’ stands for the index of the Data Block (1 – 12).