![Vigilantplant TDLS8000 Скачать руководство пользователя страница 138](http://html1.mh-extra.com/html/vigilantplant/tdls8000/tdls8000_user-manual_1022489138.webp)
<6. Configuration>
6-23
IM 11Y01D01-01EN
l
Zero calibration
Parameter
Initial value
Min. – Max.
Auto zero calibration time initiate
Disable
Select in the screen
Auto zero calibration time initiate cycle (day)
0 (=Disable)
0 – 999
Auto zero calibration time initiate cycle (hour)
0 (=Disable)
0 – 23
Auto zero calibration time initiate base clock
2010/01/01 00:00:00 2010/01/01 00:00:00 –
2068/12/31 23:59:59
Auto zero calibration gas purge time
600[s]
0 – 10,000[s]
Auto zero calibration process purge time
600[s]
0 – 10,000[s]
Auto valve control for manual zero calibration
Disable
Select in the screen
l
Span calibration
Parameter
Initial value
Min. – Max.
Pressure mode for span calibration
Process parameter Select in the screen
Temperature mode for span calibration
Process parameter Select in the screen
OPL mode for span calibration
Process parameter Select in the screen
Pressure fixed value for span calibration
101.325[kPa]
0.1 – 10,000[kPa]
Temperature fixed value for span calibration
25[deg C]
-273 – 3,000[deg C]
OPL fixed value for span calibration
0.66[m]
0.01 – 100[m]
Gas1 concentration value for span calibration
219,000[ppm]
0 – 1E6[ppm](*1)
Gas2 concentration value for span calibration
219,000[ppm]
0 – 1E6[ppm](*1)
Gas type for span calibration
Gas 1
Select in the screen
Auto span calibration time initiate
Disable
Select in the screen
Auto span calibration time initiate cycle (day)
0 (=Disable)
0 – 999
Auto span calibration time initiate cycle (hour)
0 (=Disable)
0 – 23
Auto span calibration time initiate base clock
2010/01/01 00:00:00 2010/01/01 00:00:00 –
2068/12/31 23:59:59
Auto span calibration gas purge time
600[s]
0 – 10,000[s]
Auto span calibration process purge time
600[s]
0 – 10,000[s]
Auto valve control for manual span calibration
Disable
Select in the screen
*1:
Zero is not allowed.
l
Zero + span calibration
Parameter
Initial value
Min. – Max.
Auto zero + span calibration time initiate
Disable
Select in the screen
Auto zero + span calibration time initiate cycle (day)
0 (=Disable)
0 – 999
Auto zero + span calibration time initiate cycle (hour)
0 (=Disable)
0 – 23
Auto zero + span calibration time initiate base clock
2010/01/01 00:00:00 2010/01/01 00:00:00 –
2068/12/31 23:59:59
3rd Edition: Jun. 10, 2016-00
Содержание TDLS8000
Страница 1: ...User s Manual TDLS8000 Tunable Diode Laser Spectrometer IM 11Y01D01 01EN IM 11Y01D01 01EN 3rd Edition...
Страница 10: ...ix IM 11Y01D01 01EN LT LV PL EST SLO H BG RO M CZ SK 3rd Edition Jun 10 2016 00...
Страница 25: ...Blank Page...
Страница 45: ...Blank Page...
Страница 115: ...Blank Page...
Страница 151: ...Blank Page...
Страница 231: ...Blank Page...
Страница 239: ...Blank Page...
Страница 243: ...Blank Page...
Страница 261: ...Blank Page...
Страница 303: ......
Страница 305: ......
Страница 307: ......
Страница 309: ......
Страница 311: ......
Страница 313: ...Blank Page...