VD500 Series Inverter User Manual Function Parameter Table
- 81 -
Torque
Compensation
Frequency Upper
Limit
A0-13
High Frequency
Torque
Compensation
Amount
0.0%~50.0%
3.0%
○
A0-14
High Frequency
Torque
Compensation
Frequency Upper
Limit
0.00Hz~Max frequency
25.00Hz
○
A0-15
Rotational Inertia
Compensation
Reference
0: Internal frequency
1: Feedforward frequency variation
2: Feedforward frequency
1
◎
A0-16
Feedforward
Frequency Source
Selection
0: AI1
1: AI2
2: AI3 (expansion card)
3: PULSE
4: Communication setting
0
◎
A0-17
Rotational Inertia
Compensation
Coefficient
0.00~10.00
0.00
○
A0-18
Rotational Inertia
Compensation
Upper Limit
0.0%~50.0%
5.0%
○
A0-19
Rotational Inertia
Compensation
Starting Frequency
0.00Hz~max frequency
10.00Hz
○
A0-20
Lowest Resolution
Frequency (only
effective to SVC)
0.00: Not limit
0.01Hz~2.00Hz
1.00Hz
○
A0-21
Disconnection
Detection Time
0.0: Disconnection is invalid
0.1~60.0s
0.0
○
A1 Optimize Control Parameter
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
A1-00
Carrier Frequency
0.5kHz~16.0kHz
Model
depende
nt
○
A1-01
Carrier Frequency
Adjustment with
the Temperature
0: No
1: Yes
1
○