VD500 Series Inverter User Manual Function Parameter Table
- 59 -
F6-30
T2 Disconnect
Delay
0.0s~3600.0s
0.0s
○
F6-31
DO1 Disconnect
Delay
0.0s~3600.0s
0.0s
○
F6-32
DO5 Disconnect
Delay
0.0s~3600.0s
0.0s
○
F7 AIAO Keyboard and Display
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
F7-00
JOG / REV Key
Function Selection
0: Invalid
1: Operation panel command channel
and switching with remote command
channel (terminal command channel
or communication command channel)
2: FWD/REV switching
3: Forward jog
4: Reverse jog
5: Rapid debugging
3
◎
F7-01
STOP/RESET Key
Stop Function
0: STOP/RES key stop function is
valid only in keypad operation mode
1: STOP/RES key stop function all
valid in any operation mode
1
○
F7-02
LED Running
Display Parameter
1
0000~0xFFFF
Bit00: Running frequency (Hz)
Bit01: Set frequency (Hz)
Bit02: Bus voltage (V light on
)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW
)
Bit06: Output torque (%)
Bit07: DI input state
Bit08: DO output state
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit11: AI3 (expansion card) (V)
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
BIT15: PID setting
0x001F
○
F7-03
LED Running
Display Parameter
2
0000~0xFFFF
Bit00: PID feedback
Bit01: PLC stage
0x0000
○