Function Parameter Table VD500 Series Inverter User Manual
- 74 -
FC-06
Multi-reference 6
-100.0%~100.0%
0.0%
○
FC-07
Multi-reference 7
-100.0%~100.0%
0.0%
○
FC-08
Multi-reference 8
-100.0%~100.0%
0.0%
○
FC-09
Multi-reference 9
-100.0%~100.0%
0.0%
○
FC-10
Multi-reference 10
-100.0%~100.0%
0.0%
○
FC-11
Multi-reference 11
-100.0%~100.0%
0.0%
○
FC-12
Multi-reference 12
-100.0%~100.0%
0.0%
○
FC-13
Multi-reference 13
-100.0%~100.0%
0.0%
○
FC-14
Multi-reference 14
-100.0%~100.0%
0.0%
○
FC-15
Multi-reference 15
-100.0%~100.0%
0.0%
○
FC-16
Simple PLC Run
Mode
0: Stop when single run end
1: Keep the final value when single
run end
2: Always circulation
0
○
FC-17
Simple PLC Power
Failure Retentive
Selection
Unit’s digit: power failure retentive
selection
0: Non-retentive at power failure
1: Retentive at power failure
Ten’s digit: stop retentive selection
0: Non-retentive at stop
1: Retentive at stop
0x00
○
FC-18
Run Time of
Simple PLC
Reference 0
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-19
Acceleration /
Deceleration Time
Selection of
Simple PLC
Reference 0
0~3
0
○
FC-20
Run Time of
Simple PLC
Reference 1
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-21
Acceleration /
Deceleration Time
Selection of
Simple PLC
Reference 1
0~3
0
○
FC-22
Run Time of
Simple PLC
Reference 2
0.0s (h)~6553.5s (h)
0.0s (h)
○