VD500 Series Inverter User Manual Parameter Description
- 139 -
DI input state
0x0080
AI3 voltage before
correction (V)
0x0080
DO output state
0x0100
Linear velocity
0x0100
AI1 voltage (V)
0x0200
Current power on time
(Hour)
0x0200
AI2 voltage (V)
0x0400
Current running time
(Min)
0x0400
AI3 voltage (V)
0x0800
PULSE input
frequency (Hz)
0x0800
Count value
0x1000
Communication set
value
0x1000
Length value
0x2000
Encoder feedback
speed (Hz)
0x2000
Load speed display
0x4000
Main frequency A
display (Hz)
0x4000
PID setting
0x8000
Auxiliary frequency B
display (Hz)
0x8000
If you want to show multiple parameters (switch by shift key display), only to input hexadecimal
addition results of that several parameter.
F7-04
LED Display Stop
Parameter
0000~0x3FFF
Bit00: Set frequency (Hz
)
Bit01: Bus voltage (V
)
Bit02: DI input state
Bit03: DO output state
Bit04: AI1 voltage (V)
Bit05: AI2 voltage (V)
Bit06: AI3 voltage (V)
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed
Bit11: PID setting
Bit12: Pulse input frequency (kHz)
Bit13: Set torque (0.1%)
0x0033
○
Inverter in stop state, the parameters according to the function code, which is a 16 bit binary number,
if one is 1, then the corresponding parameters can be during downtime, can see through the shift key.
If the bit is 0, then the corresponding parameters will not be displayed. The lower bits, the higher the
display priority is. Please refer to the operation display parameters detailed setting method.
Stop display parameter F7-04 corresponding table
Corresponding display parameter
Hexadecimal
Set frequency (Hz on)
0x0001