Parameter Description VD500 Series Inverter User Manual
- 162 -
1: Relative maximum frequency (F0-10), as the swing system, swing fixed.
Fb-52
Swing Frequency
Amplitude
0.0%~100.0%
0.0%
○
Fb-53
Jumping Frequency
Amplitude
0.0%~50.0%
0.0%
○
Through this parameter to determine the value of the amplitude and jumping frequency.
When setting swing relative to the center frequency (Fb-51=0), swing AW = frequency source F0-5 x
swing amplitude Fb - 52. When setting swing relative to the maximum frequency (Fb-51=1), swing
AW = maximum frequency F0-10 x swing amplitude Fb - 52.
Jumping frequency range for the swing frequency runtime, jumping frequency relative to the
frequency percentage of the swing, i.e., jumping frequency=swing AW * jumping frequency amplitude
Fb-53. If selection swing relative to the center frequency (Fb-51=0), jumping frequency is the variable
value. If selection swing relative to the maximum frequency (Fb-51=1), jumping frequency is a fixed
value.
Swing running frequency is constraints by the frequency upper limit and frequency lower limit.
+Aw
-Aw
Swing frequency amplitude
Aw=Fs et*Pb-52
Jumpi ng
frequency=Aw*Pb-53
Output frequency(Hz)
Swing frequency
upper li mit
Center frequency Fset
Swing frequency
lower li mit
Running frequency
Accelerat e according
to accel erat ion time
Swing frequency
cycle
Triangle wave
rise time
Decelerat e according to
deceleration ti me
Fig 6-30 Schematic diagram of swing frequency function
Fb-54
Swing Frequency Cycle
0.1s~3000.0s
10.0s
○
Fb-55
Triangular Wave of Swing
Frequency Rise Time
0.1%~100.0%
50.0%
○
Swing frequency cycle: a complete time value of swing frequency cycle.
Triangle wave rise time coefficient Fb-55, is a triangular wave rise time relative the time percentage of
the swing frequency cycle Fb-54.
Triangle wave rise time=swing frequency cycle Fb-54 x triangle wave rise time coefficient Fb-55, and
the unit is the second.
Triangle wave fall time=swing frequency cycle Fb-54 x (1-triangle wave rise time coefficient Fb-55),
unit for seconds.
Fb-56
Set Length
0m~65535m
1000m
○
Fb-57
Actual Length
0m~65535m
0m
○