Parameter Description VD500 Series Inverter User Manual
- 172 -
FF-10
Date of Production
(Date)
0~31
Factory
Setting
●
Product information.
FF-11
Inverter Module Radiator
Temperature
0°C~120°C
0
●
Inverter module temperature.
FF-12
Accumulative Power
Time (time lock)
0~65535h
0
●
Inverter accumulative power time.
FF-13
Accumulative Power
Consumption
0°C~65535°C
0°C
●
Show the inverter accumulative power consumption so far.
FF-14
Accumulative Run Time
0h~65535h
0h
●
Display the accumulative running time of frequency converter since the factory.
When this time reach to set running time (Fb-35), inverter multi-function digital output function (30)
output ON signal.
FF-15
Accumulative Power-on
Time
0h~65535h
0h
●
Display the accumulative power time of frequency inverter since the factory.
When this time reach to set running time (Fb-34), inverter multi-function digital output function (31)
output ON signal.
FP Factory Parameter Group
Factory set parameters, users don’t need to modify, forbidden user tries to enter the parametes group
to view or modify any of the data, otherwise it will bring unexpected circumstances and even serious
fault.