![Vela 2000-0600 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/vela/2000-0600/2000-0600_installation-and-user-manual_860580061.webp)
Chapter 2 — Decoder Command Set Guide
51
MPEG PLAY Command
Error Recovery on Data Under Flow (ErrRcvy)
Determines how the decoder handles a data starvation condition. When set to
zero (default), and when the decoder uses up all data in the DRAM buffer, the
decoder will end playback and force the screen to black. This happens when the
host is not sending data fast enough to keep up with the playback rate. This is a
fatal playback error, in which the decoder is informing the host system that play-
back has stopped. The decoder will return the following on the next
WRITE
(10):
A
RESET
BUFFER
command, new data [via
WRITE
(10)], and a new
MPEG
PLAY
command are required before playback can start again.
When set to 1, the decoder will automatically enter a Pause state when the
SCSI Status
Check Condition
Sense Key
03h Medium Error
Additional Sense Code and Qualifier
0005h End-of-Data Detected
Table 2-8. MPEG PLAY Command Format