SONET Tab
322
Out of Frequency
Threshold
Sets the threshold for which the Frequency Wide alarm
occurs. When the received Line Frequency Offset (in ppm)
exceeds the set threshold setting, the Frequency Wide alarm
will occur.
The threshold value is entered using an on-screen keypad,
and can range from
0
ppm to +/-
300.0
ppm in increments of
0.1
ppm. The default value is
0
ppm (Disabled).
Trigger Out
Trigger Out is currently not supported.
SONET Receive - Set / Set 2
Use the Set 1, Set 2 and Set 3 screens to configure the SONET Receive parameters.
The following describes the functions that appear on the Set 2 screen, depending on the
card type and configuration.
Function
Description
PLM Alarm
Reporting
Enables
or
Disables
Payload Label Mismatch alarm
reporting.