SDH Tab
444
Expected LP
Signal Label
Select one of the following values for the expected Lower
Order Path Signal:
The following options are available:
•
00 (Unequipped)
•
01 (Equipped)
•
02 (Asynchronous)
•
03 (Bit Synchronous)
•
04 (Byte Synchronous)
•
(05) ATM
•
06 (O.181 Test Signal Mapping)
•
07 (VC-AIS)
•
User Defined
- Any 3-bit value 0h to 7h
This option is only available for C-2, C-12, and C-11
mappings.
TIM Alarm
Reporting
Enables
or
Disables
Trace Identifier Mismatch (TIM) alarm
reporting.
•
A Regenerator Section Trace Identifier Mismatch (
RS-
TIM
) alarm occurs when the incoming J0 trace does
not match the Expected J0 trace setting.
•
An Higher-order Path Trace Identifier Mismatch (
HP-
TIM
) alarm occurs when the incoming J1 trace does
not match the Expected J1 trace setting.
•
A TCM Trace Identifier Mismatch (
HP-TC-TIM
) alarm
occurs when the incoming TC trace does not match
the Expected TC Trace setting, and when TC
Error/Alarm Processing is enabled.
When
Disabled
, all TIM alarms are ignored.
MPA_e_manual_D07-00-129P_RevA00
Содержание MPA
Страница 2: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 10: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 82: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 110: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Страница 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Страница 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Страница 627: ...Protocol Tabs 627 Y 1564 Conf Tab Configuration Y 1564 Test Tab Configuration MPA_e_manual_D07 00 129P_RevA00...
Страница 748: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 796: ...MPA_e_manual_D07 00 129P_RevA00...