OTN Tab
234
For OTN, each ODU layer has its own TCM (Tandem Connection Monitoring)
overhead section consisting of six TCM fields (
TCM:1-TCM:6
), including multi-level and
multi-channel ODTU Add/Drop mappings.
Quick Status Area LED's that are underlined are "Summary Status" LEDs and can be
selected to display a summary pop-up window to show the individual LEDs, and
sometimes error/alarm statistics, related to that status LED.
•
If the TCM Summary LED is red, select the "
TCM Summary
" text to display a
detailed LED window with all of the OTN TCM errors and alarms for
TCM:1
to
TCM:6
.
•
The OTN TC LEDs window appears in the center of the screen.
The following describes the TCM LEDs that appear for each of the six TCM Fields
(
TCM:1-TCM:6
).
LED
Description
BIP-8
Bit Interleaved Parity-8 error, for the specified TCM field is
being received. This is an error LED.
BEI
Backward Error Indication, for the specified TCM field is
being received. This is an error LED.
BDI
Backward Defect Indication, for the specified TCM field is
being received. This is an alarm LED.
BIAE
Backward Incoming Alignment Error, for the specified TCM
field is being received. This is an alarm LED.
Test
OTN Test Screens and Functions
MPA_e_manual_D07-00-129P_RevA00
Содержание MPA
Страница 2: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 10: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 82: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 110: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Страница 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Страница 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Страница 627: ...Protocol Tabs 627 Y 1564 Conf Tab Configuration Y 1564 Test Tab Configuration MPA_e_manual_D07 00 129P_RevA00...
Страница 748: ...MPA_e_manual_D07 00 129P_RevA00...
Страница 796: ...MPA_e_manual_D07 00 129P_RevA00...