Floor Screed Machine HD 50
50
www.utiform.com
departamento.té[email protected]
Tfno. + 34 96 570 29 82 Fax: + 34 96 570 29 83
11
Location of faults or breakdown
If the machine does not start, despite the above indications, or if it does not function normally, in the
following Table we indicate some possible reasons and their solutions.
It is assumed that the motor is correctly connected and that all the controls are in the correct position. If
the motor has stopped due to the intervention of a safety device, check the reason and correct the fault.
The following list describes the most frequent faults. If you note any irregularity which is not
included in those described below, stop the machine, analyze the gravity of the fault and contact
the nearest UTIFORM technical UTIFORM.
Whether the symptoms are of the more frequent type with recommended solutions
indicated, or not, prior to any operation the SAFETY INDICATIONS in this Manual must be
observed.
FAULT DIAGNOSIS
RECOMMENDED
SOLUTION
1. The indicator lights on the panel
do not light up on general contact.
1.1. Faulty bulbs.
1.2. Hot wire activated.
1.3. Battery disconnected.
1.4. Flat battery.
1.1.1. Fit new bulbs.
1.2.1. Disconnect the hot wire. If it trips again
check the installation as there must b e a short
circuit.
1.3.1. There may be a disconnected, broken or
sulphated battery terminal
1.4.1. Charge battery.
2. The lights go on but no start up
2.1. Do not open the diesel electro
valve.
2.2. Air in the diesel circuit.
2.1.1. Deteriorated connections to the electro
valve. Check
2.1.2. A safety device may be preventing start
up acting on the electro valve. Check safety
connections.
2.1.3. Deteriorated electro valve. Replace.
2.2.1. Drain circuit.
3. The system does not charge when
electro valve Y1 is activated
3.1. Closed aspiration.
3.1.1. Check for air leaks in the regulator
circuit.
3.1.2. Manually check to see if the aspiration
throttle is blocked.
3.1.3. Aspiration body blocked. Replace.
4. Excessive oil consumption of
Compressor
4.1. Separator filter dirty or
broken
4.2. Excess oil in the tank
4.3. Excess oil in the low grain
size material separator. Blockage
in the low grain size material
filter.
4.4. Leaks in the oil circuit
4.5. Working at low pressure.
4.1.1. Replace separator filter.
4.2.1. Check the oil level (when cold) and
empty until the requisite level is reached.
4.3.1. Low grain size material discharge
channel obstructed, dismantle and clean. If
excessively dirty replace.
4.4.1. Check the circuit and correct leaks.
4.5.1. Increase working pressure.
5. Oil comes out of the aspiration
filter when the unit stops.
5.1. The retention valve of the
aspiration body does not close.
5.1.1. Replace the aspiration device