It is possible that some of the materials used in the work could endanger health and therefore, always wear
appropriate clothing corresponding to the technical specifications provided by the manufacturer ( breathing
apparatus, gloves etc)
•
Only mix or transport materials suitable for use in the machine. (See section 2.3 correct use). If in any doubt
contact a branch of
UTIFORM.
7.2
Safety indications during normal operation
Pay particular attention to special regulations for lifting the
HD-50/07
machine.
See chapter 3.2 Crane Transport.
7.2.1 Pressure vessel
Requirements for maintenance and installation:
1. Pressure vessels are used in the HD-50/07as oil separator and mixer and pressure tank.
The operating details are indicated on the vessel identification plate:
• Maximum pressure Ps in bar,
• Maximum operating temperature, T max in ºC,
• Minimum operating temperature Min en ºC,
• Content of vessel, V in l.
2. The pressure vessel may only be used as described above, and in accordance with the technical specifications. Use
for other purposes is not permitted for safety reasons
3. The national regulations with respect to repeated testing must be observed.
4. Never carry out soldering work in the pressure vessel or any other type of procedure using heat.
5. The pressure vessel is equipped with all the protective and safety devices required, such as the pressure gauge,
protective devices to prevent pressure-rise, safety valve etc. Never start up the machine without these.
6. Clean the pressure vessels regularly with the machine unplugged and also bleed the condensate.
7. The installation, construction, and connections must not be changed.
8. The cover and the plate screws should not be used as additional attachments.
7.2.2 Safety valve
Maintenance and repair work should be carried out by the supplier’s authorized representative.
The following tests should be carried out:
1. Check once or twice a year that the elevation mechanism opens correctly. To do this, turn the cap of the
valve in an anti-clockwise direction.
2. Check annual the regulator pressure value according to local regulations. This test should not be carried
out in the compressor but in an appropriate test location
7.2.3
Accident prevention
1.
All parts which turn or move from side to side and which are not protected, may constitute a danger to
personnel and in the
HD-50/07
machine these are protected by a box or they are screwed down.