Floor Screed Machine HD 50
22
www.utiform.com
departamento.té[email protected]
Tfno. + 34 96 570 29 82 Fax: + 34 96 570 29 83
If necessary, change the transport pipes and the coupling. Note the change on the safety checklist sheet.
Where the material comes out of the mixer tank, it is possible to reduce the nominal diameter of 65 to 50
mm, thus obtaining a dual function as this will retain oversized gravel so that it does not stick in the transport pipe
and cause blockages.
The transport pipes should be able to support a working pressure of 10 bars, for fluid floor screed machines
and 40 bars for rough cast pumping or spraying machines.
6.3
Operation in closed spaces
In general, bear in mind possible applicable national regulations on working in reduced areas where the
machine is to be used.
Bear in mind that machines with diesel motors operating in closed spaces emit gases
containing carbon monoxide and so the gas should be piped outside by pipes with a
minimum diameter of 100 mm.
Locate the machine so that it does not block entry or exit areas if the doors are open.
Assemble the machine so that it is easy to work on it- not directly against a wall, to prevent hot air from the
motor being reabsorbed.
Always ensure sufficient ventilation in both the machine and the area, never block the entry of air.
Locate the machine where it will not absorb toxic substances ( such as inflammable solvents etc. but also
dust and other hazardous or toxic substances). Proximity to sparks is also dangerous.
Maintenance work, tests and repairs should take place in a clear, well aerated area.
6.4
Prior to start up
Prior to the initial start up prepare the battery for correct operation..
Check the oil level with the machine in horizontal position. If necessary, fill with oil up to the mark at the
top of the tank. Check the correct type of oil in this instruction manual
Also check the level of oil in the compressor and proceed as above.
Before removing the cap when filling with oil ensure that the pressure has been purged.
Check that the level in the fuel tank is sufficient for operation.
Remove dust from the air filters pressing the valve in the filter.
7
Operation
7.1
Safety indications
•
Bear in mind the regulations of professional bodies in the sector and all accident prevention standards.
•
Immediately rectify or remove any faults which could affect safety.