Floor Screed Machine HD 50
43
www.utiform.com
departamento.té[email protected]
Tfno. + 34 96 570 29 82 Fax: + 34 96 570 29 83
side of the lubricant recipient of the lubrication centre.
9.9
Preventive maintenance - summary table
The program we provide below provides a series of instructions, in order to obtain optimum useful life
and performance of the motor –compressor and serves as a useful guide to the machine performance (see Table
1).
The checks we propose, that is, the inspection points of 100 to 500 hours should be included in the
1,000 hour checks.
Follow the manufacturer’s instructions in the case of the motor
This table serves as a guide, as many of these operations depend on the type of work or the place and
atmosphere where the machine is running. Therefore, for example: the aspiration filter is changed when it is
broken or useless, and it will last several hours longer than those indicated if they are periodically and correctly
cleaned. The oil filter, since is it is an integral part, should be changed periodically, depending on the
circumstances; the same applies to the separator filter; as in the case of these elements, as well as for oil,
working conditions considerably influence this and duration can vary a lot.
It is advisable to keep a log book for the machine which indicates all the operations and anomalies, if
these exist, such as amount of working hours.
The instructions should be followed at all times and you should use the elements as indicated by the
factory in the corresponding instruction manuals.
UTIFORM
will not accept responsibility for breakdowns due
to unjustified or incorrect use of the machine or its accessories.
Table 1. Table providing guidelines for preventive maintenance for normal working conditions.
Running hours
Operation
8
Daily
50
Weekly
500
3
months
1000
6
months
2000
1
year
5000
2
years
8000
4
years
20000
10
years
COMPRESSOR
Check oil level
*
Clean admission filters
*
Check panel indicators
*
Check fuel level
*
Check if the radiator is clean
*
Check oil filter
*
Check separator filter
*
Change oil
* (1)
* (1)
Replace oil filter
*
Check safety devices
*
Replace aspiration filter
*
Replace separator filter
*
Clean radiator
*
Check regulation
*
Change fan belt
* (2)
Replace nylon piping and
connections
*
General Service
*
Replace cables and hydraulic hose
*
Change bearings
* (3)
Lubricate fan axle supports
*
(1)
The first change of oil and the oil filer should be carried out after 250 hours operation