release any bubbles which have formed and check the new level if necessary, correcting this by adding
more electrolyte. The level should be the same in all the battery elements.
•
Replace the cover ensuring that it is properly adjusted.
•
Mount the battery in its housing, taking special care to avoid any short circuits
•
Apply a light layer of Vaseline on the battery terminals.
•
Start the compressor.
•
Once it is in service, the battery should be maintained by checking the terminals, retightening
them and cleaning them if necessary, the electrolyte levels should also be checked, as well as the state of
charge, filling and recharging, particularly if it has been stopped for a long period.
When disposing of batteries, bear in mind the regulations on elimination of contaminating
substances. Never throw the content of batteries into the sewage system, rivers, lakes, etc.
8.7.2 Start up
•
If the start up takes place after a stoppage, wait 2 minutes.
•
Activate the general contact switch situated inside the machine (on top of the diesel tank in the
alternator zone). Check that the L1 battery pilot lights up.
•
Activate the start button, release the button and the motor will start.
•
The battery charge light (LI) should go off when the motor starts up.
• Leave the unit operating on empty for some minutes while the motor heats.
• Adjust the air taps.
If any lights remain on, immediately stop the machine and check the fault location panel.
Never keep the contact button in start up position, once the motor is functioning if you need two or three
tries to start the motor, wait until the motor stops completely before turning the key as if you do
not do this you may cause serious damage to the starter ring, or the starter motor pinion.
8.7.3
During operation
Check that the working pressure is correct and that no lights are lit on the control panel. If
this is not the case immediately stop the machine and check the fault location panel.
8.7.4
Stoppage of the compressor
•
Run the unit on empty for a few minutes.
•
Disconnect the general contact.
•
When it stops, air discharge will be heard from the ventilation valve (VN), and the air circuit
will empty and it will remain at atmospheric pressure
•
Check that the circuit pressure is at zero bar (pressure gauge PT), if it is not, check the air
circuit and the ventilation valve (VN).
•
Check the oil level of the compressor and the motor, always cold, to see whether there is
excessive oil consumption on either.
• Having carried out the above actions, the machine will be ready to start up again.
The time between stoppage and start up should be a minimum of two minutes.
DO NOT OPEN OR CLOSE the air outlet taps brusquely to avoid damaging the separator filter.