u-blox ZED-F9P Interface Description - Manual
Input Protocol Configuration of the I2C Interface (CFG-I2CINPROT-*) Configuration Defaults
Configuration Item
Key ID
Type Scale
Unit
Default Value
0x10710001
L
-
-
1 (true)
0x10710002
L
-
-
1 (true)
0x10710004
L
-
-
1 (true)
Output Protocol Configuration of the I2C Interface (CFG-I2COUTPROT-*) Configuration Defaults
Configuration Item
Key ID
Type Scale
Unit
Default Value
0x10720001
L
-
-
1 (true)
0x10720002
L
-
-
1 (true)
0x10720004
L
-
-
1 (true)
Inf Message Configuration (CFG-INFMSG-*) Configuration Defaults
Configuration Item
Key ID
Type Scale
Unit
Default Value
0x20920001
X1
-
-
0x00
0x20920002
X1
-
-
0x00
0x20920003
X1
-
-
0x00
0x20920004
X1
-
-
0x00
0x20920005
X1
-
-
0x00
0x20920006
X1
-
-
0x07 (ERROR | WARNING |
NOTICE)
0x20920007
X1
-
-
0x07 (ERROR | WARNING |
NOTICE)
0x20920008
X1
-
-
0x07 (ERROR | WARNING |
NOTICE)
0x20920009
X1
-
-
0x07 (ERROR | WARNING |
NOTICE)
0x2092000a
X1
-
-
0x07 (ERROR | WARNING |
NOTICE)
Jamming/Interference Monitor configuration (CFG-ITFM-*) Configuration Defaults
Configuration Item
Key ID
Type Scale
Unit
Default Value
0x20410001
U1
-
-
3
0x20410002
U1
-
-
15
0x1041000d
L
-
-
0 (false)
0x20410010
E1
-
-
0 (UNKNOWN)
0x10410013
L
-
-
0 (false)
Data Logger Configuration (CFG-LOGFILTER-*) Configuration Defaults
Configuration Item
Key ID
Type Scale
Unit
Default Value
0x10de0002
L
-
-
0 (false)
CFG-LOGFILTER-ONCE_PER_WAKE_UP_
0x10de0003
L
-
-
0 (false)
CFG-LOGFILTER-APPLY_ALL_FILTERS
0x10de0004
L
-
-
0 (false)
0x30de0005
U2
-
s
0
0x30de0006
U2
-
s
0
0x30de0007
U2
-
m/s
0
0x40de0008
U4
-
m
0
UBX-18010854 - R04