u-blox ZED-F9P Interface Description - Manual
Advance Information
RXM-MEASX continued
Byte Offset
Number
Format
Scaling
Name
Unit
Description
35
U1
-
flags
-
)
36
U1[8]
-
reserved4
-
Start of repeated block (numSV times)
44 + 24*N
U1
-
gnssId
-
GNSS ID (see
45 + 24*N
U1
-
svId
-
46 + 24*N
U1
-
cNo
-
carrier noise ratio (0..63)
47 + 24*N
U1
-
mpathIndic
-
multipath index (according to [1]) (0 = not
measured, 1 = low, 2 = medium, 3 = high)
48 + 24*N
I4
0.04
dopplerMS
m/s
Doppler measurement
52 + 24*N
I4
0.2
dopplerHz
Hz
Doppler measurement
56 + 24*N
U2
-
wholeChips
-
whole value of the code phase measurement (0.
.1022 for GPS)
58 + 24*N
U2
-
fracChips
-
fractional value of the code phase measurement
(0..1023)
60 + 24*N
U4
2^-21
codePhase
ms
Code phase
64 + 24*N
U1
-
intCodePhase
ms
Integer (part of the) code phase
65 + 24*N
U1
-
pseuRangeRMSE
rr
-
pseudorange RMS error index (according to [1])
(0..63)
66 + 24*N
U1[2]
-
reserved5
-
End of repeated block
Bitfield flags
This graphic explains the bits of
flags
Name
Description
towSet
TOW set (0 = no, 1 or 2 = yes)
UBX-18010854 - R04
Advance Information
Page 172 of 259