u-blox ZED-F9P Interface Description - Manual
Advance Information
CFG-LOGFILTER continued
Byte Offset
Number
Format
Scaling
Name
Unit
Description
Byte Offset
Number
Format
Scaling
Name
Unit
Description
0
U1
-
version
-
The version of this message. Set to 1
1
X1
-
flags
-
)
2
U2
-
minInterval
s
Minimum time interval between logged
positions (0 = not set).
This is only applied in
combination with the speed and/or
position thresholds.
If both minInterval and
timeThreshold are set, minInterval must be less
than or equal to timeThreshold.
4
U2
-
timeThreshold
s
If the time difference is greater than the
threshold then the position is logged (0 = not
set).
6
U2
-
speedThreshol
d
m/s
If the current speed is greater than the
threshold then the position is logged (0 = not
set). minInterval also applies
8
U4
-
positionThres
hold
m
If the 3D position difference is greater than the
threshold then the position is logged (0 = not
set). minInterval also applies
Bitfield flags
This graphic explains the bits of
flags
UBX-18010854 - R04
Advance Information
Page 52 of 259