u-blox ZED-F9P Interface Description - Manual
Advance Information
Message Structure
0xB5 0x62
0x06 0x09 (12) or (13)
see below
CK_A CK_B
Payload Contents:
Byte Offset
Number
Format
Scaling
Name
Unit
Description
0
X4
-
clearMask
-
Mask for configuration to clear (see
)
4
X4
-
saveMask
-
Mask for configuration to save (see
)
8
X4
-
loadMask
-
Mask for configuration to load (see
)
Start of optional block
12
X1
-
deviceMask
-
Mask which selects the memory devices for
saving and/or clearing operation
Note that if a deviceMask is not provided, the
receiver defaults the operation requested to
Battery Backed RAM (BBR) and Flash (if
available) (see
End of optional block
Bitfield clearMask
This graphic explains the bits of
clearMask
Name
Description
clearAll
Clear all saved configuration from the selected non-volatile memory if any bit is set
Bitfield saveMask
This graphic explains the bits of
saveMask
UBX-18010854 - R04
Advance Information